Climatic & Geographic Design Data - Jones Township

Go to content

Main menu:

Climatic & Geographic Design Data

Building Code Dept. > UCC/Permit Instructions
CLIMATIC AND GEOGRAPHIC DESIGN DATA

CLIMATIC AND GEOGRAPHIC DESIGN DATA

Ground Snow Load Wind Speed Seismic Design Catagory Weathering Frost Depth Line Termites Decay Winter Design Temp.
30" 35" See note "a" 90 mph  -3 sec burst "A" Severe 42- inches Moderate to Heavy Slight to Moderate 0º F

Note "a''  30" at elevations under 1700' in elevation;  35" at all locations over 1700' in elevation

 

SIMPLIFIED INSULATION REQUIREMENTS

Minimum U-Factor

Minimum Thermal Insulation R-Value [hrxft2xºF / BTU]

Windows & Doors Skylights Roof / Ceiling Wood Framed Walls Floors over non-conditioned space Slab Perimeter Basement Walls Crawl Spaces
0.35 0.50 R-49 R-21 R-21 R-13 /4-feet R-11 R-20
 
Copyright 2015. All rights reserved.